Crítica

Parse Server's OAuth2 adapter shares mutable state across providers via singleton instance

  • Publicada: 12.03.2026
  • Actualizado: 11.10.2026 10:22

Impact

Parse Server's built-in OAuth2 auth adapter exports a singleton instance that is reused directly across all OAuth2 provider configurations. Under concurrent authentication requests for different OAuth2 providers, one provider's token validation may execute using another provider's configuration, potentially allowing a token that should be rejected by one provider to be accepted because it is validated against a different provider's policy.

Deployments that configure multiple OAuth2 providers via the oauth2: true flag are affected.

Patches

The fix ensures that a new adapter instance is created for each provider instead of reusing the singleton, so each provider's configuration is isolated.

Workarounds

There is no known workaround. If only a single OAuth2 provider is configured, the race condition cannot occur.

References

Software afectado

Haz clic en una tecnología para ver todas sus vulnerabilidades.

PlataformaPaqueteVersiones vulnerablesCorregida en
Paquete de npm parse-server >= 9.0.0, < 9.6.0-alpha.11, < 8.6.37 9.6.0-alpha.11, 8.6.37

Referencias

Puntuación CVSS -
Vector CVSS
CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
Debilidad (CWE)
CWE-362
Plataforma
npm
Paquete
parse-server
Publicada
12.03.2026
Actualizado
11.10.2026 10:22

Fuentes y licencias

OSV / GitHub Advisory Database - GHSA-2cjm-2gwv-m892 - CC BY 4.0

Historial de vulnerabilidades: parse-server

Todas las vulnerabilidades publicadas de este paquete (Paquete de npm), de la más reciente a la más antigua. Muestra si es un fallo aislado o un paquete que hay que vigilar.

Todas (116) en el archivo
Entradas en total
116
Primera → última
06.2019 06.2026
Sin corrección
0
Explotada en ataques
0

Distribución por gravedad

  • Crítica 17
  • Alta 49
  • Media 40
  • Baja 10

Divulgaciones por año

  1. 2019: 2
  2. 2020: 4
  3. 2021: 4
  4. 2022: 12
  5. 2023: 5
  6. 2024: 4
  7. 2025: 6
  8. 2026: 79
Gravedad:
  1. Alta CVE-2026-57480 >= 9.0.0, < 9.9.1-alpha.12, < 8.6.82 9.9.1-alpha.12, 8.6.82
  2. Alta CVE-2026-47138 >= 9.0.0, < 9.9.1-alpha.1, < 8.6.77 9.9.1-alpha.1, 8.6.77
  3. Alta CVE-2026-34784 >= 9.0.0, < 9.7.1-alpha.1, < 8.6.71 9.7.1-alpha.1, 8.6.71
  4. Alta CVE-2026-34573 >= 9.0.0, < 9.7.0-alpha.12, < 8.6.68 9.7.0-alpha.12, 8.6.68
  5. Crítica CVE-2026-34532 >= 9.0.0, < 9.7.0-alpha.11, < 8.6.67 9.7.0-alpha.11, 8.6.67
  6. Alta CVE-2026-34363 >= 9.0.0, < 9.7.0-alpha.9, < 8.6.65 9.7.0-alpha.9, 8.6.65
  7. Alta CVE-2026-34215 >= 9.0.0, < 9.7.0-alpha.7, < 8.6.63 9.7.0-alpha.7, 8.6.63
  8. Alta CVE-2026-33627 >= 9.0.0, < 9.6.0-alpha.55, < 8.6.61 9.6.0-alpha.55, 8.6.61
  9. Alta CVE-2026-33539 >= 9.0.0, < 9.6.0-alpha.53, < 8.6.59 9.6.0-alpha.53, 8.6.59
  10. Alta CVE-2026-33538 >= 9.0.0, < 9.6.0-alpha.52, < 8.6.58 9.6.0-alpha.52, 8.6.58
  11. Alta · 7.5 CVE-2026-33508 >= 9.0.0, < 9.6.0-alpha.45, < 8.6.56 9.6.0-alpha.45, 8.6.56
  12. Alta · 7.5 CVE-2026-33498 >= 9.0.0, < 9.6.0-alpha.44, < 8.6.55 9.6.0-alpha.44, 8.6.55
  13. Alta · 6.5 CVE-2026-33421 >= 9.0.0, < 9.6.0-alpha.42, < 8.6.53 9.6.0-alpha.42, 8.6.53
  14. Alta · 9.1 CVE-2026-33409 >= 9.0.0, < 9.6.0-alpha.41, < 8.6.52 9.6.0-alpha.41, 8.6.52
  15. Alta CVE-2026-33163 >= 9.0.0, < 9.6.0-alpha.35, < 8.6.50 9.6.0-alpha.35, 8.6.50
  16. Alta CVE-2026-32886 >= 9.0.0, < 9.6.0-alpha.24, < 8.6.47 9.6.0-alpha.24, 8.6.47
  17. Alta CVE-2026-32944 >= 9.0.0, < 9.6.0-alpha.21, < 8.6.45 9.6.0-alpha.21, 8.6.45
  18. Alta CVE-2026-32728 >= 9.0.0, < 9.6.0-alpha.15, < 8.6.41 9.6.0-alpha.15, 8.6.41
  19. Crítica CVE-2026-32248 >= 9.0.0, < 9.6.0-alpha.12, < 8.6.38 9.6.0-alpha.12, 8.6.38
  20. Parse Server's OAuth2 adapter shares mutable state across providers via singleton instance esta entrada
    Crítica CVE-2026-32242 >= 9.0.0, < 9.6.0-alpha.11, < 8.6.37 9.6.0-alpha.11, 8.6.37
Mostrar más (20) Mostrando 20 de 66

Identifica las vulnerabilidades de tu aplicación

Con la integración de DockRay y el inventario de software activado, DockRay compara las versiones notificadas de los componentes con las vulnerabilidades conocidas y avisa de las coincidencias confirmadas. La cobertura depende de la tecnología compatible y de los avisos disponibles.

Conectar tu aplicación
Newsletter DockRay

La seguridad de tus aplicaciones en tu correo

Vulnerabilidades importantes, recomendaciones concretas y consejos prácticos para tus aplicaciones. Elige tus tecnologías y sigue lo que importa para tu proyecto.

  • Un resumen diario de nuevas vulnerabilidades, también las críticas.
  • Avisos sobre actualizaciones importantes.
  • Consejos prácticos sobre seguridad y monitorización de aplicaciones.

Déjalo vacío para recibir avisos de todas las tecnologías.

Suscripción gratuita. Date de baja con un clic en cualquier correo.