Średnia

silverstripe/framework ReadOnly transformation for formfields exploitable

  • Ujawniono: 23.05.2024
  • Aktualizacja: 11.10.2026 10:22

Form fields returning isReadonly() as true are vulnerable to reflected XSS injections. This includes ReadonlyField, LookupField, HTMLReadonlyField, as well as special purpose fields like TimeField_Readonly. Values submitted to through these form fields are not filtered out from the form session data, and might be shown to the user depending on the form behaviour. For example, form validation errors cause the form to re-render with previously submitted values by default.

SilverStripe forms automatically load values from request data (GET and POST), which enables malicious use of URLs if your form uses these fields and doesn't overwrite data on form construction.

Readonly and disabled form fields are already filtered out in Form->saveInto(), so maliciously submitted data on these fields doesn't make it into the database unless you are accessing form values directly in your saving logic.

Czego dotyczy

Kliknij technologię, aby zobaczyć wszystkie dotyczące jej podatności.

PlatformaPaczkaPodatne wersjePoprawka w wersji
Paczka Composer silverstripe/framework < 3.1.21, >= 3.2.0, < 3.2.6, >= 3.3.0, < 3.3.4, >= 3.4.0, < 3.4.2 3.1.21, 3.2.6, 3.3.4, 3.4.2

Odnośniki

Ocena CVSS 6.1/10
Wektor CVSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Słabość (CWE)
CWE-79
Platforma
Composer
Paczka
silverstripe/framework
Ujawniono
23.05.2024
Aktualizacja
11.10.2026 10:22

Źródła i licencje

OSV / GitHub Advisory Database - GHSA-97jm-g33h-f46g - CC BY 4.0

Historia podatności: silverstripe/framework

Wszystkie opisane podatności tej paczki (Paczka Composer), od najnowszej. Widać, czy to jednorazowa wpadka, czy paczka, której trzeba pilnować.

Wszystkie (93) w archiwum
Wszystkich wpisów
93
Pierwsza → ostatnia
11.2019 08.2026
Bez poprawki
1
Wykorzystywana w atakach
0

Rozkład istotności

  • Krytyczna 3
  • Wysoka 13
  • Średnia 69
  • Niska 8

Ujawnienia w latach

  1. 2019: 5
  2. 2020: 2
  3. 2021: 0
  4. 2022: 23
  5. 2023: 3
  6. 2024: 53
  7. 2025: 6
  8. 2026: 1
Istotność:
  1. Wysoka · 8.8 ghsa-265q-222x-52m6 >= 4.0.0-rc1, < 4.0.6, >= 4.1.0-rc1, < 4.1.4, >= 4.2.0-rc1, < 4.2.3 4.0.6, 4.1.4, 4.2.3
  2. Wysoka · 7.5 ghsa-cwgq-83w5-8jfq >= 4.0.0-rc1, < 4.0.5, >= 4.1.0-rc1, < 4.1.3, >= 4.2.0-rc1, < 4.2.2 4.0.5, 4.1.3, 4.2.2
  3. Wysoka · 8.8 ghsa-vcg6-8fxc-x5cq >= 3.6.5-rc1, < 3.6.6, >= 4.0.3-rc1, < 4.0.4, >= 4.1.0-rc1, < 4.1.1 3.6.6, 4.0.4, 4.1.1
  4. Wysoka · 7.5 ghsa-vgxh-x8jv-hmff >= 4.0.3-rc1, < 4.0.4, >= 4.1.0-rc1, < 4.1.1 4.0.4, 4.1.1
  5. Wysoka · 7.5 ghsa-m5q3-mvcr-gc5m >= 4.0.0-rc1, < 4.0.4, >= 4.1.0-rc1, < 4.1.1 4.0.4, 4.1.1
  6. Wysoka · 8.8 ghsa-xx4r-5265-48j6 >= 3.5.0-rc1, < 3.5.6, >= 3.6.0-rc1, < 3.6.3, >= 4.0.0-rc1, < 4.0.1 3.5.6, 3.6.3, 4.0.1
  7. Wysoka · 8.0 ghsa-mqjc-x563-c9q8 >= 3.5.0-rc1, < 3.5.6, >= 3.6.0-rc1, < 3.6.3, >= 4.0.0-rc1, < 4.0.1 3.5.6, 3.6.3, 4.0.1
  8. Wysoka ghsa-7m2v-x7rg-5hm5 >= 3.5.0-rc1, < 3.5.5, >= 3.6.0-rc1, < 3.6.2 3.5.5, 3.6.2
  9. Wysoka · 7.5 ghsa-4qx8-j9vh-2628 >= 3.5.0-rc1, < 3.5.6, >= 3.6.0-rc1, < 3.6.3 3.5.6, 3.6.3
  10. silverstripe/framework ReadOnly transformation for formfields exploitable ten wpis
    Średnia · 6.1 ghsa-97jm-g33h-f46g < 3.1.21, >= 3.2.0, < 3.2.6, >= 3.3.0, < 3.3.4, >= 3.4.0, < 3.4.2 3.1.21, 3.2.6, 3.3.4, 3.4.2
  11. Krytyczna · 9.1 ghsa-8v6m-7f5v-hhx6 >= 3.1.18, < 3.1.19, >= 3.2.3, < 3.2.4, >= 3.3.1, < 3.3.2 3.1.19, 3.2.4, 3.3.2
  12. Wysoka · 7.2 ghsa-25gq-jvx2-vg9x >= 3.1.0, < 3.1.13 3.1.13
  13. Wysoka · 8.8 CVE-2022-38148 >= 4.0.0, < 4.10.11, >= 4.11.0, < 4.11.14 4.10.11, 4.11.14
  14. Wysoka · 7.5 CVE-2020-6164 >= 4.0.0, < 4.4.7, >= 4.5.0, < 4.5.4 4.4.7, 4.5.4
  15. Wysoka · 7.5 CVE-2020-9280 >= 4.0.0, < 4.4.6 4.4.6
  16. Krytyczna · 9.8 CVE-2019-5715 >= 3.0.0, < 3.6.7, >= 4.0.0, < 4.0.7, >= 3.7.0, < 3.7.3, >= 4.1.0, < 4.1.5, >= 4.2.0, < 4.2.4, >= 4.3.0, < 4.3.1 3.6.7, 4.0.7, 3.7.3, 4.1.5, 4.2.4, 4.3.1
  17. Krytyczna · 9.8 CVE-2019-12204 >= 4.1.0, < 4.3.5 4.3.5

Dowiedz się, które podatności dotyczą Twojej aplikacji

Po podłączeniu integracji DockRay i włączeniu raportowania oprogramowania DockRay porównuje zgłoszone wersje komponentów ze znanymi podatnościami i powiadamia o potwierdzonych dopasowaniach. Zakres zależy od obsługiwanej technologii i dostępnych biuletynów.

Podłącz swoją aplikację
Newsletter DockRay

Bezpieczeństwo aplikacji w Twojej skrzynce

Najważniejsze podatności, konkretne zalecenia i praktyczne wskazówki dla Twoich aplikacji. Wybierz technologie i śledź to, co ma znaczenie dla Twojego projektu.

  • Codzienne zestawienie nowych podatności, także krytycznych.
  • Powiadomienia o ważnych aktualizacjach.
  • Praktyczne porady o bezpieczeństwie i monitoringu aplikacji.

Pozostaw puste, aby otrzymywać informacje o wszystkich technologiach.

Zapis jest bezpłatny. Wypiszesz się jednym kliknięciem w wiadomości.