Średnia

protobufjs : Schema-derived names can shadow runtime-significant properties

  • Ujawniono: 15.06.2026
  • Aktualizacja: 11.10.2026 10:22

Summary

protobufjs accepted certain schema-derived names that could collide with properties used by protobufjs runtime helpers. The known affected names are fields named hasOwnProperty, field or oneof names such as $type when loaded through protobufjs JSON/reflection descriptors, and service methods whose generated helper name is rpcCall.

When affected message or service types were used, protobufjs could read schema-controlled data where it expected an own-property helper, reflected type metadata, or the base RPC helper. This could cause deterministic exceptions or recursive calls in affected decode post-checks, verification, object conversion, reflected JSON serialization, or protobufjs RPC helper invocation.

Impact

An attacker who can provide or influence protobuf schemas or protobufjs JSON descriptors may be able to make affected message or service types unusable, resulting in denial of service for the affected processing path.

Applications using only trusted schemas are affected only if those schemas contain one of the problematic names and the application reaches the affected API path.

The issue is not known to allow code execution by itself.

Preconditions

  • The application must use an affected protobufjs version.
  • The application must load or use a schema or protobufjs JSON descriptor containing one of the problematic names:
    • a field named hasOwnProperty,
    • a field or oneof named $type through protobufjs JSON/reflection descriptor input,
    • or a service method whose generated helper name is rpcCall.
  • The application must reach the affected API path for that name: required-field decode post-checks, verify, or toObject for hasOwnProperty; reflected message JSON serialization for $type; or protobufjs RPC service invocation for rpcCall.

Workarounds

Do not load protobuf schemas or protobufjs JSON descriptors from untrusted sources with affected versions. If untrusted schemas or descriptors must be accepted, validate schema-derived field, oneof, and service method names before loading and reject the problematic names described above.

Applications using trusted schemas can avoid the issue by renaming affected fields or service methods, or by avoiding the affected API path.

Czego dotyczy

Kliknij technologię, aby zobaczyć wszystkie dotyczące jej podatności.

PlatformaPaczkaPodatne wersjePoprawka w wersji
Paczka npm protobufjs < 7.6.3, >= 8.0.0, < 8.6.0 7.6.3, 8.6.0
Paczka npm protobufjs-cli >= 2.0.0, < 2.5.1, < 1.3.3 2.5.1, 1.3.3

Odnośniki

Ocena CVSS 5.3/10
Wektor CVSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Słabość (CWE)
CWE-674, CWE-754
Platforma
npm
Paczka
protobufjs, protobufjs-cli
Ujawniono
15.06.2026
Aktualizacja
11.10.2026 10:22

Źródła i licencje

OSV / GitHub Advisory Database - GHSA-f38q-mgvj-vph7 - CC BY 4.0

Historia podatności: protobufjs

Wszystkie opisane podatności tej paczki (Paczka npm), od najnowszej. Widać, czy to jednorazowa wpadka, czy paczka, której trzeba pilnować.

Wszystkie (17) w archiwum
Wszystkich wpisów
17
Pierwsza → ostatnia
10.2018 07.2026
Bez poprawki
0
Wykorzystywana w atakach
0

Rozkład istotności

  • Krytyczna 2
  • Wysoka 6
  • Średnia 9

Ujawnienia w latach

  1. 2018: 1
  2. 2019: 0
  3. 2020: 0
  4. 2021: 0
  5. 2022: 1
  6. 2023: 1
  7. 2024: 0
  8. 2025: 0
  9. 2026: 14
Istotność:
  1. Wysoka · 7.5 CVE-2026-48712 < 7.6.1, >= 8.0.0, < 8.4.1 7.6.1, 8.4.1
  2. protobufjs : Schema-derived names can shadow runtime-significant properties ten wpis
    Średnia · 5.3 CVE-2026-54269 < 7.6.3, >= 8.0.0, < 8.6.0 7.6.3, 8.6.0
  3. Wysoka CVE-2026-44293 < 7.5.6, >= 8.0.0, < 8.0.2 7.5.6, 8.0.2
  4. Wysoka · 8.1 CVE-2026-44291 < 7.5.6, >= 8.0.0, < 8.0.2 7.5.6, 8.0.2
  5. Wysoka · 7.5 CVE-2026-44290 < 7.5.6, >= 8.0.0, < 8.0.2 7.5.6, 8.0.2
  6. Wysoka · 7.5 CVE-2026-44289 < 7.5.6, >= 8.0.0, < 8.0.2 7.5.6, 8.0.2
  7. Krytyczna · 9.8 CVE-2026-41242 >= 8.0.0, < 8.0.1, < 7.5.5 8.0.1, 7.5.5
  8. Krytyczna · 9.8 CVE-2023-36665 >= 7.0.0, < 7.2.5, >= 6.10.0, < 6.11.4 7.2.5, 6.11.4
  9. Wysoka · 7.5 CVE-2022-25878 >= 6.11.0, < 6.11.3, >= 6.10.0, < 6.10.3 6.11.3, 6.10.3

Dowiedz się, które podatności dotyczą Twojej aplikacji

Po podłączeniu integracji DockRay i włączeniu raportowania oprogramowania DockRay porównuje zgłoszone wersje komponentów ze znanymi podatnościami i powiadamia o potwierdzonych dopasowaniach. Zakres zależy od obsługiwanej technologii i dostępnych biuletynów.

Podłącz swoją aplikację
Newsletter DockRay

Bezpieczeństwo aplikacji w Twojej skrzynce

Najważniejsze podatności, konkretne zalecenia i praktyczne wskazówki dla Twoich aplikacji. Wybierz technologie i śledź to, co ma znaczenie dla Twojego projektu.

  • Codzienne zestawienie nowych podatności, także krytycznych.
  • Powiadomienia o ważnych aktualizacjach.
  • Praktyczne porady o bezpieczeństwie i monitoringu aplikacji.

Pozostaw puste, aby otrzymywać informacje o wszystkich technologiach.

Zapis jest bezpłatny. Wypiszesz się jednym kliknięciem w wiadomości.